Clear the alarm by selecting the desired station and pressing the OFF key. A station may
be disabled or eliminated from auto operation by manually turning the alarm status to
ON. This is useful if the station is in need of repair or if disabling is desired for a single
station.
Note: Disabling a station by setting its alarm status to ON does not change the length of
time a program runs. The program will still reserve a time slot during operation, but will
not energize the station.
Over Currents
Selecting this menu item will display the over current status of individual stations. Over
current alarms are set to ON if a station has an electrical problem that can cause a fuse to
blow if allowed to continue running. The status of the over current alarms may be
changed by selecting the desired stations and pressing the ON/OFF keys.
Even when a station has been electrically disabled, the time management is left in the
control of the operator.
Note: Over current protection does not operate while in the Edit mode.
Clear Flow Alarms
Clear Flow Alarms - Selecting this menu allows global clearing of all flow alarms on all
stations. Pressing ENTER will execute the command and display WAIT. When the
alarms are cleared, DONE will be displayed. Normal program operation will then
resume.
Clear Fuse Alarms
Clear Fuse Alarms - Selecting this menu item allows global clearing of all fuse alarms on
all stations. Pressing ENTER will execute the command and display WAIT. When the
alarms are cleared, DONE will be displayed. Normal program operation will then
resume.
Clear Map Alarms
Select this option to clear all remote output alarms. This includes all mapped output
communication alarms. They may be MapTo Universal, Two-Wire, or wireless outputs.
Pressing ENTER will execute the command and display WAIT. When the alarms are
cleared, DONE will be displayed. Normal program operation will then resume.
Clear Power Fail
Clear Power Failure - Selecting this menu item allows clearing of the power failure
alarm. Whenever power is lost, the power failure alarm is activated. Select Clr Power Fail
from the menu and press ENTER to clear the alarm.