Installation Procedure ____________________________________________________________To assure maximum performance from your 800S series sprinklers, re
2Connecting Hydraulic Control Tubing (Hydraulic Models Only)1. Route control tubing from the controllerto the sprinkler location(s).Note: Leave an 18&
Arc Adjustment Procedure ________________________________________________________The 835S and 855S sprinkler models can be operated in full-circle or
4Adjustment Band Angle IndicatorsThe adjustment band of the 835S and 855S have markers at predetermined arcs. By aligning the adjustment band indicato
Pilot Valve Operation (Electric Models Only) __________________________________________The main function of the pilot valve is to control the operatio
Main ValvePROBLEM POSSIBLE CAUSE – CORRECTIVE ACTIONValve won't close (a) Continuous 24 VAC to sprinkler. (Electric ) – Check controller for volt
7Service Procedures ______________________________________________________________Servicing Sprinkler MechanismNote: Refer to Figure 13 for the follo
Servicing Main Valve 1. See Warning above. To remove valve assembly, squeezesnap ring ears together with snap ring pliers (P/N 995-100)and remove snap
Servicing Pilot ValveNote: Refer to Figure 19 for the following procedure.1. Make sure that the water supply to sprinkler is positivelyshut off and an