General Specifications
Number of Gateways: Up to 4, each with up to 2 Station Groups
Number of decoder stations: up to 500
Number of Courses: 1
Number of holes per course: 48
Number of holes per system: 48
Number of Area Programs per system: 99
Number of switch controls for automation of non-irrigation functions (lights, fountains, aerators, etc.): 50
100 Hydraulic branches
Supports up to 10 weather stations and 1 hydraulic source
Area, Hole, Sprinkler based Program Architecture with Dynamic Drill down to individual stations.
Station Based Flow management for optimum system performance and reduce water time window
Automated multi-level hydraulic flow and electrical systems management (Electro-Flow)
Detailed, color-coded graphing of system projected flow
Manual adjustment factors allow for scheduling refinement by station, hole, program or course
Calculates and executes runtimes to the minute
Low voltage communication over power operations
Utilizes latching solenoid with Fail-safe Power Off protection mode
Automated adjustment factors allow scheduling refinement from 0-900%
Optional weather station and pump station alarms: Up to 99 responses for any alarm
Integration with Toro Turf Guard Soil Sensor system.
Pump Station monitoring with Flowtronex Pace Pump Station, Flowtronex Pumplog software, Watertronics WaterVision
software, Grundfos Pump Station with Toro-Grundfos Integration Service software.
User-definable names versus system defaults
On-line, context-sensitive Help screens
Advanced reporting capabilities:
Provides informational displays of the central controller status, actual watering times per station, contents of
the database, overview of scheduled irrigation activity
Allows for graphical presentation of the system projected flow, an analysis of sensor data and water usage by
the irrigation system
Reports for Water Usage
Weather data, Pump Station operation with Optional Weather ET and Pump Integration software
Hand-held radio capability
Remote sprinkler activation by area and hole address
Remote sprinkler activation by hardware address
Runtime Adjustment by percentage
Pause and resume
Station Test by area and hardware
Station activation by decoder serial number
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - General Specifications

LYNX SE CENTRAL CONTROL FOR NETWORK GDC General Specifications Number of Gateways: Up to 4, each with up to 2 Station Groups Number of decoder st

Page 2

Irrigation methods: Basic: daily run times or application amounts assigned to programs With Weather ET software option: Intermediate: run ti

Page 3 - Bidding Specifications

Bidding Specifications Central Controller The central controller shall utilize a personal-computer-based, Microsoft Windows 7 Ultimate platform, u

Page 4

The central controller shall permit true random access of all stations in the system and allow area programs to be constructed with any combinati

Page 5

The central control shall offer a Pump Integration software option shall support up to 99 alarm responses. The central controller shall provide

Comments to this Manuals

No comments