Satellite Settings
Satellite Settings allows you to set satellite parameters such as Time, Date and Language.
Use the Up or Down Arrows to navigate through the menus.
Use the Left and Right Arrow to advance to the next entry field on the same menu line.
Use the Input Dial to select values when editing.
Comm Mode:Use this menu item to select the satellite mode of operation between Central, Local or Off mode.
Hold All: Use this menu item to suspend satellite operation and choose the suspension duration from
Today, 02-30 days, Permanent or None.
Hold Rain: Use this option to suspend satellite operation and choose the suspension duration from
Today, 02-30 days, Permanent or None. When activated, Hold Rain will cancel any current
watering, along with suspending operation.
Reset Prg’s: Use this menu item to reset all satellite irrigation program by selecting Yes. After selecting
Yes, press the Up or Down Arrows to activate. The following will display:
Reset All Programs
to defaults
05 (5-second countdown)
STOP to escape
All program data will be erased after a successful reset.
Reset Sta’s: Use this menu item to reset all station settings by selecting Yes. After selecting Yes, press the
Up or Down Arrows to activate. The following will display:
Reset All Stations
to defaults
05 (5-second countdown)
STOP to escape
All station settings will be erased after a successful reset.
Reset Unit: Use this menu item to reset the satellite settings by selecting Yes. Select Yes using the Input
Dial and press the Up or Down Arrows to activate. The following will
display:
Reset All Defaults
10 (10-second countdown)
STOP to escape
After the 10-second countdown, the satellite will reboot.
Resetting the unit will erase all user-defined program data and configuration values in the
satellite’s memory.
Enable Sta’s:Use this menu item to reset all disabled stations with one execution. This function will also
clear all station alarms related to under/over current conditions. Select Yes All using the Input
Dial and press the Up or Down Arrows to activate. Select No to
cancel. Individual stations can be enabled/disabled by using the Disable function within the
Station Settings menu.
Reset Amps: The Network VP 3.0 automatically monitors the electrical output current for each individual
stations. Network VP 3.0 ensures that each station operates properly by comparing the
station’s electrical current draw to a nominal value. Use this menu item to reset all stations’
electrical current values. Select Yes All using the Input Dial and press the Up or
Down Arrows to activate. Select No to cancel. Individual stations can be reset by
using the Nominal function within the Station Settings menu.