Network VPTM 3.00 SatelliteUser’s Guide• 16 to 64 stations in eight-station increments• Field programmable for future upgrades • Does not require EPR
Pause / Resume Key The Pause command is used to suspend active program or manual irrigation. The Pause function allows the user to specify the pause d
Pause All All currently running programs, multi-manual and syringe will be suspended until the pause time-out expires. New start is allowed only for
Satellite Settings Satellite Settings allows you to set satellite parameters such as Time, Date and Language. Use the Up or Down Arrows to navigate
Setup Amps: – Use this menu item to establish and update each of the stations’ nominal current value to the satellite’s memory. These values are used
Station Settings Station Settings allows you to set parameters specific to each station. Use the Up or Down Arrows to navigate through the menus.Use
Edit Name: – Use this menu item to assign a name description to the station. The naming format is XX-AA-YYY, where XX represents the golf course hole
Scheduled Watering The Network VP satellite features 64 fully-independent resident programs. With three types of programs to select from, you can furt
Basic Irrigation Program Setting:Basic Irrigation Program example: Create Program 01 with stations 1–5 for 25 minutes each and stations 11–20 for 15 m
Advanced Irrigation Program Setting:Advance Irrigation Program example: Create program 2 with stations 6–10 for 15 minutes each with no percent adjust
13. Press the Right Arrow to advance the cursor to the next entry field. This entry field will indicate the runtime in hours, minutes and seconds (
IndexRadio Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3Fuse and Circuit Breaker Specifications - - - - - - - - - -
7. Press the Down Arrow to advance the cursor to the Delay: field. This delay time will determine the wait time between program cycles. Use the Inp
5. Press the Down Arrow to advance to the Sta field. Use this field to enter the station numbers that corresponds to the currently displayed sequen
Manual Watering The Manual Watering functions are used for additional watering if the irrigation program is not sufficient. They can also be used to
Syringe - Choose Syringe to activate all the stations in a selected irrigation program for a specified runtime. Note: The Maximum number of simultaneo
% (Percent) Adjust The percent adjust function allows you to fine tune irrigation programs. With weather conditions changing constantly, Percent Adjus
Menu: Station Amps – Use this menu item to review each of the station’s last recorded voltage amperage, nominal amperage value, tolerance value, alar
26Troubleshooting GuideElectrical Protection1 - Main Power Switch / 1.5A Circuit Breaker - Protects the controller from a short circuit on the incomi
27LED Indicators10 - Pump Relay LED Indicator - When illuminated, the pump relay is activated.11 - Common Relay LED Indicator - When illuminated, th
28Lithium Battery Replacement ProcedureA 3.9V Lithium battery (P/N 363-2200) is installed behind the timing mechanism circuit board to sustain the con
Radio SpecificationsEquipment Type – Data radio, MAXON, model SD-125 U2Frequency Band – UHFRF Output Power – 2.0 wattCurrent Consumption:Standby (Mute
IntroductionThe Toro Network VPTM Satellite combines modular flexibility, ease of use and increased programmability in a single controller. Modularit
Timing Mechanism Components1 Left and Right Arrows allow you to select the next entry field within the same menu line. Any changes will be saved aft
Distribution Board Components1 5V, 9V and 12V LED Indicator - When illuminated, the LED indicates the presence of the corresponding voltage in the sa
Pump / Common Board Components1 Pump Terminal Switch - The Pump terminal can be placed in ON, OFF or Auto with this switch.2 Common Terminal Switch
Power-Up DiagnosticsUpon power-up, the satellite will display:Network VP BootingThe Network VP Satellite will initiate a diagnostic test automatically
If the satellite has an active running program, the display will read:Sun 04/02/06 02:31 pm Sat# 001-001 Sec: 57 Running 04 prg+ Man (Running