Edit Name: Use this menu item to assign a name description to the station. The naming format is XX-AA-
YYY, where XX represents the golf course hole number, AA represents the area description
acronym and YYY represents the sprinkler number within the area. By following the naming
format, you can easily figure out where and what area the station is watering.
Area Description Acronym Listing
GR = Greens DR = Driving Range TE = Tee CH = Club House FW = Fairways
LA = Landscape RF = Rough PG = Putting Green AP = Approaches MS = Misc.
Last On: This menu item will display the last activation current value that the satellite recorded for the
station.
Nominal: This menu item will display the nominal current value that the satellite recorded for the station.
You can reset the value by selecting Reset. Use the Input Dial to select Reset and
press Up or Down arrows to select. Once Reset is selected, Nominal values will
default to 0 (Zero). The satellite will record the new value on the next station activation.
Note: Nominal values can also be updated by activating Setup Amps from the Satellite
Settings menu or selecting Reset from the Nominal item under Station Amps menu in Diagnostics.
Performing these function will reset all of the station’s nominal current values.
Tol +/– : Use this menu item to set the individual station’s nominal current tolerance. This value
will determine the station’s allowable current operating range. If the satellite subsequently
determines that the station is operating outside of the allowable range, the satellite will disable
the station and generate an alarm.
Alarm EventsThis menu item will display any alarm events incurred from previous activation. Alarm event
messages will disappear when the satellite detects that the fault has been fixed.
Pump Nomn: This menu item will display the pump output nominal current value. This value can not be
modified in this menu item. To reset this value, select Reset from the Nominal: menu item. This
value will also reset when Setup Amps from the Satellite Settings menu is activated.